N50 Series is an integrated board type product based on T50 Series. The series has high performance to configure various systems/applications at economical cost. With its powerful communication function and excellent control characteristics, N50 is exclusively used for semiconductor test equipment of global companies.
Power Supply | Rating 100~240V AC 50~60Hz (voltage operating range: 85~265V AC) * Option: Rating 24V AC or DC (operating voltage range 20~28V DC) |
|
---|---|---|
Power Consumption | 5VA (Max.) | |
Input Type | TC : K, J, T, E, R, B, S, L, N, U, C(W5), D(W3) Platinum RTD: KPt100(KS), JPt100(JIS), Pt100(DIN) Current input (A): 4~20mA DC Voltage input (V): 1~5V DC, -10~20mV DC, 0~100mV DC |
|
Display Accuracy | ¡¾0.3% of FS + 1 Digit | |
Input ImpedanceInput | Current input(250§Ù), Voltage input(includingTC) ¡Ã 1M§Ù min. (RTD line resistance: ¡Â 10§Ù , when 3-line resistance are the same) |
|
Sampling Period | 50~250ms (variable according to SG-PID algorithm) | |
Control Output | Voltage (S.S.R) | DC15V 25mA (Built-in short protection circuit) Voltage pulse (time proportional PID output) |
Current (S.C.R) | 4~20mA DC, load impedance ¡Â 600§Ù (continuous PID output) | |
Control Method | Super 2 degree-of-freedom PID (SG-PID algorithm), Fast, Auto-Tuning | |
Communication Output | 2 wires RS485 totally independent isolation structure Max. speed : 19,200bps / Max. connect no. 99 devices (32 devices recommended) Support protocol : PC-Link, TL-Link, Modbus-ASCII, Modbus-RTU, Sync-Master/Slave | |
Ambient Temperature and Humidity | - 10~50¡ÆC/ relative humidity 25~85% RH (but with neither condensation nor freezing) | |
Weight (B/K, Accessories included) | Main Board : 60g / Display Board : 35g / Connectable Cable : 24g |